- 16:2816:28, 24 June 2022 diff hist 0 N File:HEI2.jpg No edit summary current
- 16:2816:28, 24 June 2022 diff hist 0 N File:HEI1.jpg No edit summary current
- 16:2416:24, 24 June 2022 diff hist +498 N Coated CMP Example, Low-Hazard Dam Created page with "<div style= "text-align:center;">''Message: CMP conduits can be coated with PVC to prevent corrosion''</div> ----</br> This Fergus County, MT dam was rehabilitated following failure using a PVC coated CMP. Extra caution is advised when installing coated CMP, a tiny nick can start the process of corrosion. <gallery mode="slideshow"> File:RP1.jpg|Outlet end of pipe File:RP2.jpg|Outlet of new CMP File:RP3.jpg|Inlet structure with coated CMP </gallery> Category:Example..."
- 16:2416:24, 24 June 2022 diff hist 0 N File:RP3.jpg No edit summary current
- 16:2416:24, 24 June 2022 diff hist 0 N File:RP2.jpg No edit summary current
- 16:2416:24, 24 June 2022 diff hist 0 N File:RP1.jpg No edit summary current
- 16:1716:17, 24 June 2022 diff hist +5,966 N Replacement Created page with "Conduit replacement is achieved by excavating the embankment, removing the existing conduit, and replacing with a new conduit. Common replacement pipe material types include Corrugated Metal Pipe, Concrete Pipe, and Plastic Pipe. Several important questions to ask include: #Is the existing means of control adequate? Is the gate / valve in a good condition, location, with no operational problems? If not, an evaluation of outlet configurations should be first. #The next ch..."
- 15:5915:59, 24 June 2022 diff hist +1 Conduit / Pipe Rehabilitation No edit summary
- 15:5815:58, 24 June 2022 diff hist +39 N Filter Diaphram Exhibits Camrenbt moved page Filter Diaphram Exhibits to Filter Diaphragm Exhibits current Tag: New redirect
- 15:5815:58, 24 June 2022 diff hist 0 m Filter Diaphragm Exhibits Camrenbt moved page Filter Diaphram Exhibits to Filter Diaphragm Exhibits
- 15:5615:56, 24 June 2022 diff hist +1,023 N Filter Diaphragm may Require Downstream Pipe Replacement or Extension Created page with "<div style= "text-align:center;">''Message: Consider installing a downstream sand filter during any outlet conduit rehab/replacement.''</div> ----</br> A highway occupies the crest of this dam in Southeast Alaska. The dam functions as a dam, highway, and utility causeway. The inlet structure was in poor condition and the outlet conduit needed to be either replaced or rehabilitated. The project was designed as a slipline to prevent the need to close down the highway duri..."
- 15:5615:56, 24 June 2022 diff hist 0 N File:ADF12.png No edit summary current
- 15:5615:56, 24 June 2022 diff hist 0 N File:ADF11.png No edit summary current
- 15:5515:55, 24 June 2022 diff hist 0 N File:ADF10.png No edit summary current
- 15:5515:55, 24 June 2022 diff hist 0 N File:ADF9.png No edit summary current
- 15:5515:55, 24 June 2022 diff hist 0 N File:ADF8.png No edit summary current
- 15:5515:55, 24 June 2022 diff hist 0 N File:ADF7.png No edit summary current
- 15:5515:55, 24 June 2022 diff hist 0 N File:ADF6.png No edit summary current
- 15:5415:54, 24 June 2022 diff hist 0 N File:ADF5.png No edit summary current
- 15:5415:54, 24 June 2022 diff hist 0 N File:ADF4.png No edit summary current
- 15:5415:54, 24 June 2022 diff hist 0 N File:ADF3.png No edit summary current
- 15:5415:54, 24 June 2022 diff hist 0 N File:ADF2.png No edit summary current
- 15:5315:53, 24 June 2022 diff hist 0 N File:ADF1.png No edit summary current
- 15:4515:45, 24 June 2022 diff hist +1,289 N Filter Diaphragm Exhibits Created page with "<div style= "text-align:center;">''Message: Place as far downstream as possible, extending up to the normal reservoir elevation''</div> ----</br> A filter diaphragm is a designed zone of filter material constructed around a conduit. This zone can act both as a drain to carry off water and as a filter to intercept soil particles being transported by the water. A filter diaphragm is an important component of design for both new construction and the renovation of older emb..."
- 15:4415:44, 24 June 2022 diff hist 0 N File:FDE5.jpg No edit summary current
- 15:4415:44, 24 June 2022 diff hist 0 N File:FDE4.jpg No edit summary current
- 15:4415:44, 24 June 2022 diff hist 0 N File:FDE3.jpg No edit summary current
- 15:4415:44, 24 June 2022 diff hist 0 N File:FDE2.jpg No edit summary current
- 15:4315:43, 24 June 2022 diff hist 0 N File:FDE1.jpg No edit summary current
23 June 2022
- 22:4222:42, 23 June 2022 diff hist 0 Internal Repair of Isolated Damage (Joint) No edit summary
- 22:4122:41, 23 June 2022 diff hist +724 N Internal Repair of Isolated Damage (Joint) Created page with "<div style= "text-align:center;">'Message: Internal sleeves can be used to repair isolated damages in conduits.''</div> ----</br> Internal sleeves are used to repair damaged areas of conduits. Common sleeve materials are rubber and sheet metal. Sleeves can be used to rehabilitate concrete, steel, and plastic pipes ranging from 8 inches to 138 inches. Content From www.vip-polymers.com <gallery mode="slideshow"> File:ISR1.jpg|Typical Sleeve Configuration File:ISR1.jpg|S..."
- 22:4122:41, 23 June 2022 diff hist 0 N File:ISR5.jpg No edit summary current
- 22:4022:40, 23 June 2022 diff hist 0 N File:ISR4.jpg No edit summary current
- 22:4022:40, 23 June 2022 diff hist 0 N File:ISR3.jpg No edit summary current
- 22:4022:40, 23 June 2022 diff hist 0 N File:ISR2.jpg No edit summary current
- 22:4022:40, 23 June 2022 diff hist 0 N File:ISR1.jpg No edit summary current
- 22:3222:32, 23 June 2022 diff hist 0 N File:2CE7.jpg No edit summary current
- 22:3222:32, 23 June 2022 diff hist +893 N CIPP Example 2 Created page with "<div style= "text-align:center;">''Message: CIPP can work well for slightly deformed pipes''</div> ----</br> Cured in place pipe was chosen as the rehabilitation alternative for this Powell County Dam for many reasons: 1) the dam was 45 feet high, so pipe replacement would have been a major effort; 2) although the host CMP pipe was beginning to deteriorate, it did not have visible holes; 3) the host CMP pipe was slightly deformed into an oblong shape, thus it was necess..."
- 22:3222:32, 23 June 2022 diff hist 0 N File:2CE6.jpg No edit summary current
- 22:3222:32, 23 June 2022 diff hist 0 N File:2CE5.jpg No edit summary current
- 22:3122:31, 23 June 2022 diff hist 0 N File:2CE4.jpg No edit summary current
- 22:3122:31, 23 June 2022 diff hist 0 N File:2CE3.jpg No edit summary current
- 22:3122:31, 23 June 2022 diff hist 0 N File:2CE2.jpg No edit summary current
- 22:3022:30, 23 June 2022 diff hist 0 N File:2CE1.jpg No edit summary current
- 22:2222:22, 23 June 2022 diff hist +151 CIPP Example 1 No edit summary
- 22:2222:22, 23 June 2022 diff hist 0 N File:1CE2.jpg No edit summary current
- 22:1822:18, 23 June 2022 diff hist +799 N CIPP Example 1 Created page with "<div style= "text-align:center;">''Message: CIPP Increased 36-in diameter CMP Pipe Strength.''</div> ----</br> A 36-in CMP was rehabilitated using CIPP technology. After curing, the pipe demonstrated a significant increase in culvert pipe strength. The ultimate load bearing strength increased from 1,377 pound force foot (lbf/ft) to 3,095 lbf/ft, and the D-Load strength increased from 689 pound force per square foot (lbf/sq. ft) to 1,548 lbf/sq.ft. Content Courtesy of U..."
- 22:1822:18, 23 June 2022 diff hist 0 N File:1CE1.jpg No edit summary current
- 22:0822:08, 23 June 2022 diff hist +2,373 N ⚠ Cautions for CIPP in Large Diameter Conduit Created page with "<div style= "text-align:center;">''Message: Extra care should be taken to fully expand CIPP liner against large diameter conduit''</div> ----</br> CIPP was used on this project to rehabilitate an old bituminous coated 48-inch corrugated metal pipe. The downstream portion of the old CMP was replaced with a new reinforced concrete pipe (RCP) and the upstream portion of the old CMP was slip lined with CIPP. The CIPP was installed through an access point at the gate tower a..."
- 22:0822:08, 23 June 2022 diff hist 0 N File:CFC13.jpg No edit summary current